> Details > Specification  
  Air Oasis™ Nano Induct Air Purifier!
The ONLY Induct Air Purifier with Rotational UV Shield Technology!
 
 
  Power Source
The Nano Induct  was designed for continuous operation 24/7.
26VDC wall adapter 
The Nano Induct  is powered by a 26 VDC power adapter with a rated input voltage of 100 - 240 VAC and 6 foot supply cord. The adapter connects to a 110 or 230 VAC 3 amp power cord that is 5 feet in length. The AC power cord is detachable and interchangeable to meet global requirements. For safety and to ensure proper function of the Nano Induct  we recommend that ONLY the power adapter included with the original purchase be used.
Optional 24 VAC Internal HVAC Power Source Wiring
Most forced-air heating or cooling systems are  equipped with an internal 24 VAC power source, to which the Nano Induct can be safely connected without overloading other circuits.

Indicator Lights

The unit has two indicator lights that tell specific information about the NANO Induct.
  • Green: Unit has power, ballast and UVC lamp are operating efficiently.
  • Red: Unit has power, UVC lamp is defective or not properly connected. Contact an Air Oasis™ representative.
  • Blue Solid: The UVC lamp is within its two year life span. No action is needed.
  • Blue Flashing: The UVC lamp is outside its two year life span and should be replaced.
  • No Lights: There are two possibilities.
    • The unit is not properly connected to the power supply.
    • The ballast exceeded the operating temperature of 105˚C. The thermal protector opened the circuit, disconnecting power to the ballast. The circuit automatically resets when the ballast cools.

Coverage
As a general recommendation:
  • Nano Induct NIND 6 should be used in areas up to 1000 sq. ft.
  • Nano Induct NIND 9 should be used in areas up to 3000 sq. ft. and
  • Nano Induct NIND 14 should be used for areas between 3000 and 5000 sq. ft.
Areas of higher contamination, areas above 5000 square feet or with ceilings above 10 feet may require additional units for best results.

Noise

  • Zero operational noise

Advanced Technologies
  • AHPCO Nano Catalyst Technology
  • Longlife+™ Specialty Lamp Coating
  • Rotational UV Shield Technology
  • Since UV lamps were first used in HVAC systems, there have been constant complaints from engineers and contractors that UV light can degrade rubbers and plastics causing premature failure of the HVAC system.

    Therefore Air Oasis™ created the perfect solution. With the development of our proprietary "Rotational UV Shield", you can control the amount of UV light emitting from the unit, allowing a constant stream of air to pass through the AHPCO Cell for treatment.


Low Maintenance
  • The Nano Induct was engineered to be virtually maintenance free.

AHPCO Cell Replacement
  • The AHPCO Cell should be replaced every two years.

Outer Housing Maintenance
  • Never use harsh cleaners, chemicals or abrasives on the plastic polycarbonate housing or anodized aluminum. Only a dry micro fiber towel or a towel lightly moistened with water should be used to remove any dust or other debris from the outside of the unit.


Warranty and Guarantee
  • The Nano Induct comes with a 2 year warranty
Eliminates Odors
  • Smoke odors
  • Pets odors
  • Food odors
  • and more...
Reduces Contaminates
  • Aeroallergens
  • Mold
  • Bacteria
  • Viruses
  • VOC
Energy Efficient
All Air Oasis™ Nano Induct Air Purifier use less energy than a 45 watt light bulb, saving you money and saving the environment every day.

Placement Options and Applications
The Nano Induct are designed to be installed within the ductwork of an HVAC system. They can be mounted in either the supply side or return side of your HVAC system. The Nano Induct should be placed within 10 feet of an electrical outlet.

Above coils
The Nano Induct unit should be mounted directly above the coils with UV Shields rotated 90˚ to the open position. The unit should be orientated so that the UV light shines directly on the coils (“air flow” label should be pointing at the coils). Larger air handlers may require multiple units.

Reduce contaminants in ductwork
In residential or light commercial applications a single unit can be mounted in the plenum on the supply side of the HVAC system.

In large commercial applications
Air can become recontaminated as it travels through the duct work. Therefore it may be necessary to mount several Nano Induct units throughout the ductwork. The UV Shield can be rotated to the closed position when installing the unit in close proximity to rubber seals and gaskets or electrical components to protect them from the UV rays. When possible, the UV Shield should be rotated the open position for optimal efficiency to expose more contaminants to UVC radiation.

Reduce airborne contaminants in a room
The Nano Induct unit should be installed in close proximity to the air outlet vent that supplies air to the room being treated. The UV Shield should be rotated to the closed position to prevent human exposure to UV rays.

Use for The multiple applications
Nano Induct units are intended for removal and mineralizing airborne contaminations of pathogens and/or harmful molds and volatile organic compounds(VOC)  present in rooms or enclosed areas.